FIRE PUMP HOUSE UNITS

THE PACKAGED SYSTEM: NAFFCO Fire Pump House Units are designed as per customers’ specification and NFPA 20 requirements.
Complete fire pump set assembly is fixed inside an intermodal container with all fire pump related standard accessories, valves and fittings and pump testing instruments. In addition to these fire pump set components the container also includes lighting and necessary fire protection equipment for the pump house such as a standalone heat detector and fire extinguishers. All internal wiring and piping is done at factory and external connectors are provided external to the side of the container thatenables easy piping connections and gland plate is welded on the bottom edge at one side of the container for power supply cable entry at field.

All the major fire pump components such as Fire Pumps, Drivers, Controllers, Valves, Pressure Gauges and Flow Meter are UL and / or FM Certified as required by the NFPA 20 standard. Only high quality components and fittings are used in order to ensure reliable performance and long life.
Only suction and discharge piping, diesel engine exhaust line, test line return, drain pipe and power input connections need to be made at field. The complete package is thoroughly tested and inspected prior to dispatch.

Actual components may vary subject to individual project requirements and commercial offer. We reserve the right to change the specifications without any prior notice.  

Only those NFPA 20 requirements will be complied that are possible within the space limitations of pump house design.

Contact Us to Purchase
Specifications

Electric Pump

• Electric Motor
• Diesel Engine
• Diesel Pump
• Jockey Pump
• Gate Valve – Suction
• Gate Valve – Discharge
• Gate Valve – Test Header
• Non Return Valves (Fire Pumps)
• Flow Meter
• Internal Exhaust Pipe Line
• External cable entry provision
• Electric Fire Pump Controller
• Diesel Fire Pump Controller
* THE STANDARD COMPONENTS INCLUDED IN THESE HOUSED FIRE PUMP SYSTEMS ARE AS FOLLOWS:
• Jockey Pump Controller
• Pressure Sensing Line
• Drain Pipe Lines
• Pump Shaft Drain
• Floor Drain
• Battery
• Pressure Gauge on Discharge
• Header
• Fuel Tank with Drip Tray
• Fuel Tank Air Vent Pipe Line
• Non Return Valve (Jockey)
• Gate Valve – Discharge
• Suction Pressure Gauge
• Discharge Pressure Gauge
• Discharge Header
• Emergency Light
• Interior Weather Proof Lights
• CO₂ – 5 Kg
• DCP – 6 Kg
• ADCP – 6 Kg
• Sprinkler System with ZCV.
• Casing Relief Valve.
• Ventilation Fans with Louvers
• Sand trap Louvers
• Suction Pipe Line
• Discharge Pipe Line
• Complete Internal Conduit Wiring


ADVANTAGES

• Comparably less project site space requirement
• Easy field installation
• Shortened installation time
• Reduced on-site labor cost
• Trouble free commissioning
• Optimum inside free space allocation
• Single unit responsibility
• Single manufacturing source
• Pre-connected internal piping
• Complete equipment on single base
• Perfect system operational integrity
• In-built auxiliary systems as per NFPA standard
• Convenience in obtaining parts and services
• Certified major components
• Assured compliance with NFPA 20
• Eliminates on-site assembly of components
• Long lasting pump house enclosure
• Superior quality painting of pum house
• High strength lifting lugs
• Extensive range of component selections
• Wide variety of configurations

Contact Us

Subscribe to stay up to date on all the latest news

Click one of our representatives below to chat on WhatsApp.